SRI Logo
Spacer
    

Spacer
         
  SRI Logo

Contact SRI Biosciences

In Vivo Assessment of Diabetes

SRI currently offers in vivo models for Type I and Type II Diabetes, including Diabetic Neuropathy Testing. 

Type I Diabetes models include:

  • Non-obese diabetic mice (NOD) and related strains, model of spontaneous Type 1 diabetes (T1D) autoimmune disease. 
  • Multiple Dose Streptozotocin (MD-STZ) Induced Diabetes (mice and rats)  

Type II Diabetes models include:

  • Streptozotocin (STZ) Induced Diabetes (mice and rats)
  • Alloxan Induced Diabetes (mice and rats)

Blood Glucose Testing

We perform various types of glucose tests:

  • oral glucose tolerance test (OGTT)
  • post prandial (rodent chow meal test)
  • intraperitoneal glucose tolerance test (IPGTT)
  • intravenous glucose tolerance test (IVGTT)          

Blood glucose can be measured on a fasting basis (collected after an 8 to 10 hour fast), randomly (anytime).  Blood glucose is monitored with a regular glucose meter or Analox Instrument for more accurate readings or for glucose levels >600 mg/dL-900 mg/dL (5 µl sample)).

Diabetes Rescue Model (mice or rats)

  • Transplantation of pancreatic islets into the kidney capsule of diabetic animals.
  • Nephrectomy—removal of the graft should cause hyperglycaemia— to reverse diabetes            

Streptozotocin (STZ) Induced Diabetic Neuropathy* (rats)

* The von Frey Monofilament Test is used to measure mechanical allodynia. 

Other related models:

  • Continuous Monitoring of Drinking Water or other liquids using an automated cage system. The system can record the drinking pattern (24/7 undisturbed) in normal and/or diabetic rats.
  • Micturition (urine production or metabolites) monitoring using an automated cage system. 
  • Microsurgical Implant and Characterization of Medical Device Prototypes (e.g., glucose sensor testing and other components).
  • Insulin pellets and device implants for slow release of insulin and/or insulin like compound delivery.

    Compound delivery include:  Intrathecal catheter (Yaksh's method), kidney capsule, intravenous, oral, subcutaneous, intradermal, intranasal, patch implant, Alzet and/or external pump placement.  Please ask if you need a custom design method of delivery or specific microsurgery.

 

      


Contact SRI Biosciences

 

       Last Updated Jun 10, 2010

 

About Us  Vertical divider  R&D Divisions  Divider  Careers  Divider  Newsroom  Divider  Contact Us
©2012 SRI International 333 Ravenswood Avenue, Menlo Park, CA 94025-3493
SRI International is an independent, nonprofit corporation. Privacy policy